Veroval® and Thermoval®
There are many behavioural risk factors for the development of hypertension, including:
In addition, there are several metabolic factors, including:
Secondary causes might be:
In some cases there is no known specific cause for hypertension. Genetic factors may play a role.
Cardiovascular risk is a person's risk of developing a cardiovascular disease (CVD).
The exact cause of CVD isn't clear, but there are lots of things that can increase the risk of getting it. These are called "risk factors". The more risk factors you have, the greater your chances of developing CVD.
The main risk factors for CVD are outlined below.
The more of these risk factors apply, the higher the cardiovascular risk.
Cardiovascular disease (CVD) is a general term for conditions affecting the heart or blood vessels. CVDs are usually associated with a build-up of fatty deposits inside the arteries (atherosclerosis) and an increased risk of blood clots. They can also be associated with damage to arteries in organs such as the brain, heart, kidneys and eyes.
There are many different types of CVD. Four of the main types are:
To determine your blood pressure, two values have to be measured:
The measured values for blood pressure are displayed in mmHg.
To better evaluate the results, Veroval® blood pressure monitors offer a traffic light colour system that directly describes the results to enable easier categorisation of the measured value. The World Health Organisation (WHO) and the European Society of Cardiology (ESC) & European Society of Hypertension (ESH) have developed the following summary for classifying blood pressure values:
| Results indicator | Evaluation | Systolic pressure | Diastolic pressure | |
| Red | Grade 3 hypertension1 | above 179 mmHg | and/or | above 109 mmHg |
| Orange | Grade 2 hypertension1 | 160 - 179 mmHg | and/or | 100 - 109 mmHg |
| Yellow | Grade 1 hypertension1 | 140 - 159 mmHg | and/or | 90 - 99 mmHg |
| Green | High normal1 | 130 - 139 mmHg | and/or | 85 - 89 mmHg |
| Green | Normal1 | 120 - 129 mmHg | and/or | 80 - 84 mmHg |
| Green | Optimal1 | 90–119 mmHg | and | 60 - 79 mmHg |
| Orange | Hypotension (low blood pressure)2 | up to 89 mmHg | and/or | up to 59 mmHg |
Classification of blood pressure taken in practice and definition of hypertension grade.
1 2018 ESC/ESH guidelines.
2 National Health Service, 2023.
The decision about which type of blood pressure monitor to use is mostly a matter of personal preferences. Regarding the requirements for technical measurement accuracy, clinical tests and tests for legal conformity, there are no differences between wrist and upper arm devices, so basically you could use every Veroval® blood pressure monitor.
However, there are certain advantages to each of the device types which you can consider when making your decision:
If you already suffer from cardiovascular diseases such as cardiac arrhythmias, the upper arm blood pressure monitor Veroval® duo control should be your first choice for measuring your blood pressure daily. To ensure high precision even with cardiac arrhythmias, the Veroval® duo control measures blood pressure with DUO SENSOR technology.
In addition to cardiac arrhythmias, we recommend upper arm devices for people with vascular diseases, diabetes mellitus and for users over the age of 60. Due to the constriction of the vessels, it is easier to obtain more accurate values with upper arm devices. For accurate blood pressure readings, the correct position of the cuff at heart level during the measurement is very important. This is particularly easy with an upper arm device, as it is already ensured when the cuff is applied to the arm. For users who are unable or find it difficult to apply an upper arm cuff, a wrist device is recommended. Reasons for this can be too-large upper arms, obesity, or limited mobility.
In case you are not affected with either one of the conditions mentioned above, and you are looking for an easy to handle device, a wrist blood pressure monitor offers fast measurement and convenient handling. For your best personal health, we recommend choosing the model you feel most comfortable with, because what matters most is that you measure your blood pressure frequently and regularly at home.
Please read the instruction leaflet carefully before using your Veroval® product for the first time, since correct blood pressure measurement requires correct operation of the device. These instructions will guide you through the individual steps for measuring your own blood pressure. You will be given important and useful hints to ensure that you obtain reliable results for your personal blood pressure profile.
Many factors play a role in blood pressure measurement. The ten general rules help you to measure correctly.
Your blood pressure values change naturally many times a day. Most fluctuations are normal and caused for example by the time of the day, physical activity, stress or weather. Our internal clock influences and controls the daily sequence of many processes in our body, including blood pressure.
Fluctuations are therefore natural, and blood pressure usually has a daily pattern with two natural peaks during the course of the day:
Morning: blood pressure reaches its highest level, usually in the first two hours after awakening.
Noon to early afternoon: values drop slightly.
Evening: blood pressure rises again and reaches a second high point.
Night: blood pressure drops to its lowest level, which is often about 10 to 15% lower than the daytime value.
Veroval® blood pressure monitors follow the recommendations of the European Society of Hypertension (ESH) and differentiate between measurements taken in the morning and those taken in the evening. With this information, your doctor is more likely to identify the right treatment for you if you should need medical treatment for high blood pressure.
If you notice irregular or high fluctuations in your daily blood pressure, there is an increased risk of circulatory disease, which should be checked by your doctor.
The contraction of the heart muscle is stimulated by electrical signals. A disorder of these electrical signals is called an arrhythmia. This may be due to genetic predisposition, stress, age, lack of sleep, exhaustion or similar factors. A doctor can establish whether an irregular heartbeat is the result of an arrhythmia.
The Veroval® blood pressure monitors indicate possible irregular heartbeats with the IHB (irregular heart-beat) indicator.
Why is this function so important?
If you see the IHB symbol regularly when measuring your blood pressure, we recommend that your doctor checks your heart rhythm. Please discuss with your doctor whether taking your own blood pressure readings is appropriate for you.
Veroval® blood pressure monitors indicate possible irregular heartbeats with the following symbol:
Atrial fibrillation is the most common cardiac arrhythmia and can only be detected when it occurs. It is characterized by a markedly accelerated, constantly irregular heartbeat. When atrial fibrillation occurs, the atria can no longer properly support the heart chambers during pumping. As a result, the heart does not empty completely and blood remains in the atria, where it can form clots. These clots can enter the brain and trigger a stroke.
Signs of atrial fibrillation are often unspecific, such as palpitations, dizziness, shortness of breath or chest pain. Up to 30% of the people who suffer from atrial fibrillation do not feel any symptoms at all.
Stroke prevention is especially important for people over the age of 50, or people suffering from hypertension, diabetes or hyperlipidemia. In general, there are two important factors which are accountable for heart attacks and particularly strokes: these are high blood pressure and irregular heartbeat, particularly atrial fibrillation.
The good news is that more than 80% of strokes can be prevented. Beside some non-influencable risk factors, such as old age, being male, family history or having already suffered a stroke, you can reduce your stroke risk by:
(Not all of the symptoms occur or appear at the same time)
The human body regulates the body temperature to a target value, although body temperature can fluctuate by up to 1 °C over the course of a day. Throughout the course of life, your average body temperature can decrease by up to 0.5 °C. Moreover, the temperature inside the body (core temperature) and the surface temperature on the skin have different values. Thus, there is no ‘normal’ body temperature – it always depends on the measurement site.
|
|
|||
| Measurement site |
|||
| Description | Ear / forehead | Rectum | Mouth / armpit |
| Normal temperature | 35.8 - 36.9 | 36.3 - 37.4 | 35.9 - 37.0 |
Fever is an elevated temperature of the human body that is substantially beyond the normal range.
Depending on the thermometer you use and on the measuring site you choose (depending on which measuring site your thermometer is suitable for), the table below gives you an orientation if your child has fever or if the result of the temperature measurement corresponds to a normal body temperature.
| Measurement site |
|||
| Description | Ear / forehead | Rectum | Mouth / armpit |
| Subnormal temperature | <35.7 | <36.2 | <35.8 |
| Normal temperature | 35.8 - 36.9 | 36.3 - 37.4 | 35.9 - 37.0 |
| Elevated temperature | 37.0 - 37.5 | 37.5 - 38.0 | 37.1 - 37.5 |
| Slight fever | 37.6 - 38.0 | 38.1 - 38.5 | 37.6 - 38.0 |
| Moderate fever | 38.1 - 38.5 | 38.6 - 39.0 | 38.1 - 38.5 |
| High fever | 38.6 - 39.4 | 39.1 - 39.9 | 38.6 - 39.5 |
| Very high fever | 39.5 - 42.0 | 40.0 - 42.5 | 39.6 - 42.0 |
Available measurement methods:
The state of the art is to measure body temperature either with a digital pen-type thermometer or with an infrared thermometer. Digital pen-type thermometers have been established for rectal, oral and axillary measurement of body temperature, whereas infrared thermometers measure the body temperature on the forehead or in the patient´s ear.
The devices placed in the market by HARTMANN correspond to the standards for clinical thermometers, and operate within those defined tolerances. All above-mentioned methods are therefore suitable for measuring body temperature.
However, the digital thermometers from HARTMANN have better accuracy, with a deviation of +/– 0.1 °C for the entire measuring range, compared to the infrared thermometers which have a measuring accuracy of ±0.2 °C at 35.0 °C – 42.0 °C (for more detailed information please see the respective product instructions for use). Forehead temperature measurement is also more dependent on external influences than rectal, oral or axillary measurement.
Digital pen-type thermometers from HARTMANN measure the body temperature directly, that means the heat emanating from the respective body site (rectum, mouth, armpit) is transferred to the measuring sensor of the device. The duration of this measurement process until the measurement result is displayed on the device depends on the thermometer model and the measurement location on the body. The fastest possible measurement can be achieved using a rapid model and applying it in the rectum. When measuring in the mouth, you have to follow some rules, and when measuring under the armpits, you should add 0.5 °C to the displayed value to get a more realistic value. Digital pen-type thermometers are long-lasting and accurate.
Infrared thermometers from HARTMANN measure the infrared radiation emitted from the eardrum or from the skin on the forehead of the body, and convert the measured values into a body temperature. The eardrum is easy to access and is supplied with blood from the same vessels as the hypothalamus, the temperature control centre of the body. Hence in the ear you get the fastest fever reaction, and therefore measuring in the ear is suitable for monitoring the progress of a fever. When measuring on the forehead, the temperature result is established mainly from the temporal artery. A forehead measurement can be performed with or without contact with the skin, depending on the device model. This measurement method eliminates the need to physically insert a probe into a body cavity such as the ear canal or rectum. The accuracy of the measured values depend on careful handling. Clinical infrared thermometers have been well-established in the market for decades.
Which thermometer/measurement method is most appropriate for you may depend on different conditions, such as disease, age, anatomy, personal preference.
For more detailed informations please see IFU of the respective products.
Used correctly, the Veroval® infrared thermometers provide reliable results for both measurement methods.
In direct comparison, however, ear measurement is usually superior to forehead measurements. Why? The ear measurement method is ideal for accurate temperature control because the eardrum is very well supplied with the same blood as the vessels for the hypothalamus, which is responsible for the thermoregulation of our body. Temperature changes can be measured quickly, and the progress can be monitored easily. In addition, this measurement method is less susceptible to interference from exogenous factors.
In the end, the measurement accuracy of both methods depends mainly on their correct use.
Clean the device and the measuring sensor with a moist cloth and a mild detergent or a suitable disinfectant, e.g. 70% isopropyl alcohol solution (active substance: 2-propanol).
For non-waterproof thermometers:
Make sure no liquid can penetrate the inside of the thermometer, and never immerse the device in water or other cleaning agents!
For waterproof thermometers:
Do not immerse the thermometer in liquid for longer than 30 minutes, and do not immerse it any deeper than 15 cm
Please do not use any aggressive cleaning agents or solvents, as these can damage the device and cause the display to become opaque.
Body temperature measured in the ear and on the forehead can be influenced by several factors. Please follow some rules for precise measurements:
Contact free infrared thermometers use a modern measuring sensor technology to provide a body temperature value of high measurement accuracy. It is the most advanced and safest method of measuring the body temperature currently on the market. It is convenient as well as easy to use.
A non-contact forehead thermometer allows measurement of the temperature of babies, children and adults to be taken without skin contact in only 3 seconds. The thermometer is simply moved across the forehead over the temporal artery: a positioning light integrated into the head of the sensor enables guided handling of the thermometer during the scanning process. This eliminates the need to physically insert a probe into a body cavity such as the ear canal or rectum, which is not always well received by very sick children and babies. When a non-contact thermometer is used, you can take your child‘s temperature even while he or she is sleeping, absolutely silently and without bothering or even waking him or her.
Contact-free body temperature measurement is safe and hygienic because the temperature is measured without skin contact. The risk of contact transmission of bacteria or viruses is minimized. Therefore Veroval® baby is ideal for use on babies and children.
Veroval® baby additionally allows the measurement of the surface of an object or the room temperature in a further measuring mode. It can therefore be used in multiple ways.