Cosmopor I.V. transparent

The main function of Cosmopor I.V. transparent is the sterile and mechanical covering and fixation of cannulae/catheters. Cosmopor I.V. transparent allows visual control of the puncture site without dressing change thanks to the transparent film window. The waterproof characteristics of the film provide a barrier against water, bacterial penetration and external contaminants. The dressing facilitates the free passage of water vapour and gases, allowing the skin to breathe. The rounded corners prevent it from rolling up, while the high degree of adhesiveness and the included fixation strips allow the dressing to remain firmly in place during the wear time. The dressing conforms to body contours. Medical assessment of the puncture site and surrounding skin is needed to determine when the dressing needs to be changed

 

  • Produse
  • Aplicatie
  • Documente
  • Multimedia

Produse

38196

Cosmopor I.V. transparent are non-active, single-use, self-adhesive, sterile devices consisting of a coated backing material laminate with a fenestration (covered with PU-film, to allow the observation of the cannulae/catheters during the application of the dressing) and an I.V. opening for the cannula insertion, protected with silicone paper, and including self-adhesive fixation strips attached to the silicone paper, for the sterile covering and fixation of cannulae/catheters.

 


Cosmopor I.V. transparent

53854

Cosmopor I.V. transparent are non-active, single-use, self-adhesive, sterile devices consisting of a coated backing material laminate with a fenestration (covered with PU-film, to allow the observation of the cannulae/catheters during the application of the dressing) and an I.V. opening for the cannula insertion, protected with silicone paper, and including self-adhesive fixation strips attached to the silicone paper, for the sterile covering and fixation of cannulae/catheters.

 


steril, ambalat individual

Informatii Produs 6x5 cm
Numar Articol
9008170
Continut
1 Cutie din 100 bucati
EAN
4052199501086
Informatii Produs 9x7cm
Numar Articol
9008180
Continut
1 Cutie din 100 bucati
EAN
4052199501116
Informatii Produs 12x10 cm
Numar Articol
9008190
Continut
1 Cutie din 50 bucati
EAN
4052199501147
Informatii Produs Numar Articol Continut EAN
steril, ambalat individual
6x5 cm
Numar Articol 9008170
1 Cutie din 100 bucati 4052199501086
9x7cm
Numar Articol 9008180
1 Cutie din 100 bucati 4052199501116
12x10 cm
Numar Articol 9008190
1 Cutie din 50 bucati 4052199501147

Aplicatie

36815
  1. Remove the fixation strips from the protective cover number 1 and use them to fixate the catheter, cannula wings, cannula needle and/or tubes. The removal and application of the fixation strips can also be performed after the complete application of Cosmopor I.V. transparent to further fixate the cannula/cannula wings and the dressing itself (please see step 4). If that is the case, do not dispose of the protective cover number 1 until removal and application of the fixation strips.
  2. After removing the protective cover number 1, apply the dressing with the transparent window centered on the cannula insertion/exit site. Please note that in the case of Cosmopor I.V. transparent 12x10cm, the upper side of protective cover number 3 may be used as an additional gripping point to precisely position the dressing.
  3. Release protective cover number 2 from the dressing´s legs and apply them onto the catheter, cannula and/or cannula wings. Gently press the entire dressing onto the skin, conforming it to the body contours and the cannula or catheter shape for a secure fixation.
  4. For Cosmopor I.V. transparent 12x10cm, carefully remove the remaining protective cover number 3 afterwards, then apply the upper part of the dressing onto the skin.
  5. The application of the fixation strips may also be performed after step number 3 to further fixate the catheter, cannula, cannula wings and/or tubes (if applicable) and the dressing itself. Removal To safely remove or change Cosmopor I.V. transparent after its individual application time, carefully remove the fixation strips, then loosen an edge of the dressing´s legs and remove them completely. Once the legs have been removed, the cannula must be pressed carefully against the puncture site, so the cannula needle does not move. Then the rest of the dressing must be stretched and removed in its totality, avoiding the cannula‘s and needle‘s movement.

Documente

ECDOC_100257218.pdf

DoC_MDD_Cosmopor i.V. transparent

ECDOC_100394718.pdf

PHAG_Cons. EU DoC_MDR_Class I sterile

IFU_100375808.pdf

IFU Cosmopor IV transparent GM