DISINFACTS | Issue 2/2026

STUDIES Glove disinfection in emergency situations An alternative to hand disinfection plus changing gloves? As changing gloves, including hand disinfection, is time-consuming, disinfecting examination gloves could represent a viable alternative [4]. Until now, however, there has been a lack of research into the integrity of disinfected medical examination gloves under realistic conditions. HARTMANN and the NOTIS e.V. Emergency Medicine Training Centre have now investigated the compatibility of gloves with a hand disinfectant, as well as the effect of mechanical stress on glove material, in a simulation study [5]. Peha-soft® Nitrile Fino examination gloves withstand disinfection in practical testing Thirteen healthcare professionals who were trained in accordance with the Basic Life Support and Advanced Cardiovascular Life Support standards, respectively, took part in the study. For half of the exercises, the Peha-soft® Nitrile Fino nitrile gloves were disinfected using Sterillium® med hand disinfectant. Once the exercises were complete, the worn gloves were collected and tested for barrier integrity in accordance with DIN EN 455-1:2024-11, Part 1 [6]. Of the 1,175 gloves tested – 606 untreated and 569 disinfected – 12 (1%) failed the test, including nine untreated and three disinfected gloves. This means Emergency situations, such as cardiopulmonary resuscitation (CPR), are characterized by significant time pressure. This often leads to infection control, particularly hand disinfection, being neglected [1]. However, recent studies show that hand disinfection could be performed in over half of cases without delaying CPR [2, 3]. Fig. 1: Number of gloves that passed and failed the test in accordance with DIN EN 455-1:2024-11; Part 1 [6]. Sources 1. Bushuven S et al. (2024) Int J Nurs Stud Adv 6: 100207. https://doi. org/10.1016/j.ijnsa.2024.100207. 2. Bushuven S et al. (2023) Front Med (Lausanne) 9: 1025449. https://doi. org/10.3389/fmed.2022.1025449. 3. Bentele M et al. (2024) Infect Prev Pract 7: 100418. https://doi. org/10.1016/j.infpip.2024.100418. 4. Scheithauer S et al. (2016) J Hosp Infect 94: 268–272. https://doi. org/10.1016/j.jhin.2016.08.007. 5. Bentele M et al. (2026) Integrity of medical examination gloves after disinfection - Results from Basic and Advanced Life Support; Poster presented at the DGHM Congress 2026. Available via HARTMANN SCIENCE CENTER: https://www.hartmann-science-center.com/en/topissues/events/dghm-2026 6. DIN EN 455-1:2024-11. Single-use medical gloves – Part 1: Requirements and testing for leak-tightness; German version of EN 455-1:2020+A2:2024. Key findings at a glance • In the tested setting, mechanical stress following disinfection with Sterillium® med had no effect on the barrier integrity of Peha-soft® Nitrile Fino examination gloves. • 99.5% of the disinfected gloves and 98.5% of the untreated gloves passed the DIN EN 455-1 test. • The results support the implementation of glove disinfection in emergency situations without compromising glove quality. • Although repeated disinfection affected mechanical properties, including force at break, the magnitude of these effects may vary between glove materials. Consequently, extrapolation to other examination gloves and hand disinfectants requires additional testing. AQL: Accepted Quality Limit (= permissible defect rate) The AQL specifies how many parts in a given sample size may have defects. The exact limit values for different sample sizes and batch sizes are set out in ISO 2859-1. In the European Union, disposable examination gloves have a standard AQL of 1.5. For a sample size of 200 gloves, this means a maximum of 7 defecte gloves to pass the test. The next better AQL value of 1.0 would, by definition, mean that there would be 5 defective gloves in a random sample of 200 gloves. ?! that 98.5% of the untreated gloves and 99.5% of the disinfected gloves were intact (see Fig. 1). The expected defect rate was below 3.5%, confirming the Acceptable Quality Limit (AQL) target of 1.5—both with and without glove disinfection. The Peha-soft® Nitrile Fino gloves tested here even have an AQL of 1.0 and, according to the standard definition, maintain this value even after disinfection. Direct comparisons revealed no differences in frequency of tears between groups, regardless of the hand on which the gloves were worn (right vs. left) or glove size. The findings of this study therefore support the efforts to ensure that hygiene is implemented correctly in emergency situations. native gloves 98.5 % disinfected gloves 99.5 % 9

RkJQdWJsaXNoZXIy NDU5MjM=