STUDIES EN 1500: Reduce contact time to 15 seconds? Interlaboratory test lays the groundwork for a possible amendment to the standard In practice, however, the actual rub-in times observed during hygienic hand disinfection are often significantly shorter than the specified 30 seconds [2]. An interlaboratory test organized by the Association for Applied Hygiene (VAH) investigated whether reducing the rubbing time to 15 seconds in the EN 1500 standard protocol is methodologically reliable and reproducible [2]. Fourteen laboratories from Germany, Austria, Italy and Malaysia participated in the interlaboratory test. They investigated a modified EN 1500 procedure involving 3 ml of 60% isopropanol and a rub-in time of 15 seconds. The established procedure involving 2 × 3 ml of 60% isopropanol and 2 × 30 seconds of rubbing time served as the reference. In a randomized crossover design, the participants’ hands were first artificially contaminated with Escherichia coli K12. Following hand disinfection, the reduction in bacterial count was determined [2]. In order to be suitable for hygienic hand disinfection, a disinfectant must demonstrate its bactericidal efficacy in accordance with EN 1500 standard using a reference method involving a standardized rubbing procedure and a minimum contact time of 30 seconds [1]. Efficacy was lower than that of the reference method Good reproducibility and repeatability were observed in all laboratories. Despite the shorter rubbing time, the method remained statistically stable. On average, however, the efficacy was lower than that of the reference method. In 13 out of 14 laboratories, lower log₁₀ reductions were achieved with a rubbing time of 15 seconds than with the reference method over 30 seconds. One laboratory reported comparable efficacy for both rubbing times. Carrying out the six-step rubbing technique in 15 seconds proved challenging. No significant influence of hand size on efficacy was observed. The interlaboratory test thus provides an important scientific basis for amending EN 1500 to reduce the rubbing time. However, further validation is necessary to ensure efficacy and user safety [2]. Sources 1. DIN EN 1500-2013: Chemical disinfectants and antiseptics – Hygienic handrub – Test method and requirements (phase 2/step 2). 2013. 2. Roesch KM et al. (2026) J Hosp Infect 171:227–235 Of all healthcare-associated infections (HAI), 85% are caused by bacteria, 10% by viruses and around 5% by yeasts [5]. Moulds are responsible for only 0.3% of HAI in Europe [5]. Whilst yeasticidal disinfectants are effective against yeasts, such as Candida albicans, disinfectants that are also effective against filamentous fungi or moulds, such as Aspergillus brasiliensis, are referred to as fungicidal. However, fungicidal efficacy is generally not required for hygienic hand disinfection because yeasts, unlike moulds, are transmitted via direct skin contact. Therefore, disinfectants with a yeasticidal spectrum of activity, such as Sterillium®, cover the yeasts that are relevant to hand disinfection. Essential for hand disinfection: yeasticidal activity Sources 3. S2k Guideline on Hand Disinfection and Hand Hygiene, AWMF Register No. 075-004, Class 2k guideline, as at 3 February 2023 https://register.awmf.org/assets/ guidelines/075-004l_S2k_Haendedesinfektion-und-Haendehygiene_2023-09.pdf (accessed on 18 August 2026). 4. https://www.aktion-sauberehaende.de/files/public/fileadmin/ash/user_upload/pdf/Positionspapiere/ASH_Positionspapier_15_Sekunden_01072020.pdf (accessed on 18 August 2026) 5. European Centre for Disease Prevention and Control. Point prevalence survey of healthcare-associated infections and antimicrobial use in European acute care hospitals. Stockholm: ECDC; 2024. https://www.ecdc.europa.eu/sites/default/files/documents/healthcare-associated-point-prevalence-survey-acute-carehospitals-2022-2023.pdf (accessed on 18 August 2026). 6. Sakita K et al. (2017) Microb Pathog 113:225–232 18
RkJQdWJsaXNoZXIy NDU5MjM=